Lab Technician Interview Questions and Answers
26 questions to prepare for your Laboratory Technician interview
Overview
A laboratory technician interview tests whether you produce results someone can trust and work safely. This guide covers research and university labs, industrial quality control labs (food, pharmaceutical, environmental and manufacturing) and clinical labs. Expect behavioural questions about errors and near misses, technical questions on safety, solutions, calibration and QC, and scenarios such as a failed control. Panels often include the lab supervisor and a senior technician or technologist, and some employers add a practical or written test. Clinical labs differ most: they ask about specimen identification, critical values and Westgard rules, and may check your certification or registration.
Have five or six stories ready, each told as situation, task, action and result: an error you caught, a result you had to troubleshoot, a safety near miss, an SOP you followed or fixed, a busy day you prioritized and a disagreement over data. Rehearse the math aloud: molarity, C1V1 = C2V2 and serial dilutions. Read the posting for the instruments and methods it names, and look up the lab's accreditation and what it tests. Bring your transcript, your WHMIS certificate, any certification or registration documents and a one-page list of the instruments you have run, with model names.
Get Your Free Laboratory Technician Interview Prep Guide
Get practical tips, sample answers, and a checklist to prepare for your interview.
No spam. Unsubscribe anytime. We respect your privacy.
How to answer
The interviewer is checking whether you review your own work and stop a result when something looks wrong. Pick one concrete catch: a transcription slip between an instrument printout and the LIMS, a calculation that used the wrong dilution factor, or a sample ID that did not match the worklist. Explain what tipped you off, which person you alerted, how you corrected the record with a traceable entry, and what changed afterwards, such as a second-person check. Pitfall: a story where someone else found your error and you fixed it only after being told.
How to answer
This tests troubleshooting method. Walk through it in order: the signal you noticed (a negative control that came up positive, a peak in the blank, mixed colonies on a plate), holding the results, then changing one variable at a time: reagent lots, water, consumables, technique, instrument, environment. Name what you found, such as [a contaminated buffer stock or carry-over after a high sample], and the fix, such as aliquoting reagents or adding a wash step. Pitfall: blaming the instrument or a reagent lot without evidence, or a story that ends without a change that stopped it happening again.
How to answer
Supervisors want proof that you report near misses instead of shrugging them off. Describe the event plainly, such as [a centrifuge started with unbalanced tubes, a glove that tore while handling a corrosive, or a solvent stored next to an oxidizer], then what you did in the moment, who you told, the incident or near-miss form you filed, and the change that followed. Mention the training or SOP it pointed back to. Pitfall: claiming you have never seen a safety problem, which suggests you were not looking.
How to answer
The interviewer is checking that you follow procedures and still use judgement. A strong answer shows you raised the problem through the right channel: you told your supervisor or quality assurance (QA), recorded any departure as a deviation, and suggested wording for the revision, which then went through document control. Sample outline: "The SOP listed [a buffer recipe that no longer matched the validated method]. I flagged it before the run, we used the method's version under a documented deviation, and QA issued revision [4]." Pitfall: describing a shortcut you took without telling anyone.
How to answer
This tests prioritization without cutting corners. Explain your order: in a clinical lab, STAT requests and specimens with short stability, such as blood gases or ammonia; in a QC lab, release and in-process samples holding up production; in environmental testing, samples close to their holding-time limit. Then show how you batched similar tests, told your supervisor early what would be late, and kept QC frequency unchanged. Pitfall: saying you skipped controls or second checks to clear the backlog.
How to answer
This is a data integrity question. The panel wants to know you will not delete an outlier, rerun until a result passes or back-date an entry because a researcher, client or production manager is waiting. Describe the pressure, what you said and how you escalated to your supervisor or QA. In a regulated lab, mention that an out-of-specification result triggers an investigation under the SOP and that every data point stays in the record. Sample line: "I can't remove that replicate, but I can flag it and start the investigation today." Pitfall: a story that ends with you giving in.
How to answer
Clinical panels ask this to check you follow the critical value policy under pressure. Walk through it: confirm the result is valid (acceptable QC, no clot, hemolysis or labelling problem), phone it to the responsible nurse or physician within the time your policy sets, have them read back the result and two patient identifiers, and document who received it, when, and the read-back. If you cannot reach anyone, escalate through the chain your policy names. Pitfall: leaving the result in the laboratory information system (LIS) for someone to notice, or giving it to a person not authorized to receive it.
How to answer
Interviewers ask this because mixing them up is dangerous. A ducted chemical fume hood draws air away from you and exhausts it outside, protecting you from vapours; it does nothing for the sample. A Class II biological safety cabinet (BSC) uses HEPA-filtered airflow to protect you, the sample and the room from biological aerosols. Most Class II cabinets recirculate part of their air, so they are unsuitable for volatile toxic chemicals unless built and ducted for that use. Pitfall: treating a clean bench, which protects only the sample, as a safety cabinet.
How to answer
This checks that you read hazard information before opening a bottle. On the supplier label: product identifier, pictograms, signal word (Danger or Warning), hazard and precautionary statements, and supplier details. On the 16-section SDS, name the sections you use: 2 (hazards), 4 (first aid), 6 (accidental release), 7 (handling and storage), 8 (exposure controls and PPE, such as glove material) and 10 (stability and reactivity). A decanted container usually needs a workplace label with the product name, safe handling precautions and a reference to the SDS. Pitfall: choosing gloves out of habit.
How to answer
Canada uses containment levels (CL1 to CL4) where US labs say biosafety levels. The Canadian Biosafety Standard sets the requirements, and the Public Health Agency of Canada regulates Risk Group 2 and higher human pathogens under the Human Pathogens and Toxins Act. At CL2, describe a door separating the lab from public areas, biohazard signage, entry limited to authorized staff, a lab coat and gloves, a certified BSC for aerosol-generating work, waste decontaminated in the zone or moved out in sealed, leak-proof containers, and reporting incidents to your biological safety officer. Pitfall: using risk group and containment level interchangeably.
How to answer
This checks lab math. Molarity is moles of solute per litre of solution, so mass = molarity × volume (L) × molar mass: [0.1 M] × [0.5 L] × 58.44 g/mol for sodium chloride = [2.92 g]. Dissolve it in less than the final volume, then make up to the mark in a volumetric flask. For dilutions, C1V1 = C2V2: [10 mL] of [1 M] stock made up to [100 mL] gives [0.1 M]. A 1:10 dilution is 1 part sample plus 9 parts diluent. Label contents, concentration, date and initials. Pitfall: dissolving solute in the full final volume.
How to answer
This checks calibration habits and technique. Balance: confirm it is level, warm and draft-free, then run and record the daily check with certified weights; full calibration follows a schedule, often by an outside service. Pipettes: gravimetric checks (weigh dispensed water and convert to volume) against the tolerances in your SOP, often based on ISO 8655. Technique: pre-wet the tip, press to the first stop before aspirating with the pipette near vertical, dispense through to the second stop, change tips between samples and use reverse pipetting for viscous or volatile liquids. Pitfall: using a pipette past its calibration date.
How to answer
The interviewer wants routines you follow every day. pH meter: calibrate before use with at least two fresh buffers that bracket your samples, rinse and blot the electrode between buffers, and check slope and offset against your SOP limits; slow or drifting readings point to a failing electrode. Spectrophotometer: the Beer-Lambert law (A = εlc) makes absorbance proportional to concentration within the linear range, so zero on a reagent blank, read standards to build a calibration curve, and dilute any sample that reads above the top standard. Pitfall: reporting a result read beyond the highest standard.
How to answer
The interviewer wants the principle and your daily habits. ALCOA+ means data are attributable, legible, contemporaneous, original and accurate, plus complete, consistent, enduring and available. In practice: record results directly in the notebook, worksheet or LIMS as you work, in permanent ink, dated and initialled; keep raw data such as printouts and chromatograms; correct errors with a single line through the entry, the right value, your initials, the date and a reason. A validated LIMS records every change in an audit trail. Pitfall: writing results on a glove or scrap paper and copying them later.
How to answer
This shows whether you understand why controls exist. Name them: blanks catch contamination, duplicates show precision, spikes show recovery, and reference materials or controls show accuracy. Clinical labs plot controls on Levey-Jennings charts and apply Westgard rules: 1-2s is a warning; reject on 1-3s (one control beyond 3 SD), 2-2s (two consecutive beyond the same 2 SD limit), R-4s (one above +2 SD and one below -2 SD in a run), 4-1s (four consecutive beyond the same 1 SD limit) or 10x (ten consecutive on one side of the mean). Pitfall: rerunning a control until it passes.
How to answer
The panel is checking whether you understand chromatography beyond pressing start. Explain the basics: compounds separate as they pass through a column, retention time compared with a reference standard identifies a compound, and peak area quantifies it against a calibration curve. Before reporting, confirm system suitability passed (resolution, tailing factor, plate count, precision of replicate standard injections), the blank shows no interfering peaks, bracketing check standards stayed within limits and integration is consistent. GC suits volatile compounds; HPLC suits non-volatile or heat-sensitive ones. Pitfall: manually reintegrating peaks to make a result pass without a documented reason.
How to answer
The interviewer wants to hear that nothing is released on a failed control. Hold the results, look for the cause (wrong control lot, expired or poorly mixed reagent, calibration drift, instrument error codes), fix it, recalibrate if needed and rerun QC. Then retest the samples run since the last acceptable QC. Tell your supervisor and whoever is waiting, with a new time, and document the failure and corrective action. In a pharmaceutical or food QC lab, a failing product result goes through the out-of-specification (OOS) investigation procedure. Pitfall: releasing results because the failure "looked like a fluke".
How to answer
This is a patient safety question. Do not relabel or test the specimen. Follow the rejection policy: set it aside, record the reason, notify the collecting unit so it can be recollected, and file an occurrence report. Correct labels carry two patient identifiers, such as full name and date of birth or health card number, plus collection date and time. Irreplaceable specimens, such as cerebrospinal fluid, may go through an exception process with the collector's sign-off. In an industrial lab, quarantine a mismatched sample at login and contact the submitter. Pitfall: fixing the label yourself after a phone call.
How to answer
This tests whether you speak up without making it personal. If there is immediate risk, say so on the spot: "Can you move that into the hood? The SDS calls for local exhaust." Otherwise talk to them privately soon after. If it keeps happening or someone was exposed, report it to your supervisor or the health and safety committee member and file a near-miss report. You can mention that occupational health and safety law in Canada gives workers the right to refuse unsafe work and a duty to report hazards. Pitfall: staying quiet because the colleague is senior.
How to answer
The interviewer wants a calm, documented response. Make it safe first: stop the run, power down if needed and contain any leak. Note which samples were analyzed and which were not, return the rest to the right storage conditions and check their stability or holding times. Tag the instrument out of service, log the fault and call your supervisor or the service contact. Agree whether to move samples to a backup instrument or a partner lab. Before running again, recalibrate and run QC, and have results from the interrupted run reviewed. Pitfall: reporting partial results without checking them.
How to answer
This checks spill response and waste handling. Alert people nearby and remove ignition sources; evacuate and call for help if the spill is larger than your SOP allows or is in a confined space. For a small spill within your training, check SDS section 6, put on the right PPE, contain it from the outside in with spill kit absorbent, collect it in a sealed, labelled hazardous waste container, and report it. Segregate waste: halogenated and non-halogenated solvents apart, acids apart from bases, oxidizers away from organics, sharps and biohazards in their own containers. Pitfall: mopping it toward a drain.
How to answer
Labs testing legal, regulatory or forensic samples rely on chain of custody: a signed record of everyone who held a sample, when and why, often backed by tamper-evident seals. The interviewer is checking that you know a broken chain or a failed acceptance check can invalidate the result. Record the condition on receipt (seal, temperature, container, holding time), quarantine the sample and contact the client or submitter. Test only if they accept it with the condition noted on the report, as your SOP allows. Pitfall: logging it in as normal and fixing the paperwork afterwards.
How to answer
Panels want a reason tied to this setting. For a research lab, talk about method development, variety and learning from scientists. For an industrial QC lab, talk about routine testing done well, working to a specification and the release decisions your results support. For a clinical lab, connect the work to patient care and say you are comfortable with shift work, STAT pressure and strict specimen rules. Then link your answer to one thing you know about this employer. Pitfall: an answer that would fit any lab, or one that treats a QC job as a stepping stone to research.
How to answer
Before the interview, look up what the lab tests and its accreditation. Testing and calibration labs are often accredited to ISO/IEC 17025, which covers validated or verified methods, traceable calibration, proficiency testing and controlled records; medical labs to ISO 15189. In Canada, testing labs often hold Standards Council of Canada accreditation, while medical labs usually go through a program their province requires, such as BC's Diagnostic Accreditation Program. Then say what that means for you: controlled SOPs, traceable records and proficiency testing. Pitfall: calling the lab "ISO certified", since labs are accredited and certification usually means ISO 9001.
How to answer
This is the weakness question in lab form. Choose a real gap that does not touch safety or data integrity, and show the plan. Good examples: limited time on [GC-MS] that you are closing through a vendor course or supervised runs; slow troubleshooting on unfamiliar instruments; little exposure to reviewing and approving results in a LIMS. Name the step you have already taken and how you would get up to speed here. Pitfall: offering "I sometimes rush documentation" or "I find routine work boring", which are close to dealbreakers in a lab.
How to answer
Ask questions that show you have pictured the daily work. Good choices: "Which instruments and methods would I run in my first few months?", "How is training signed off before I work independently?", "How does the lab handle a QC failure or a deviation?", "What does the shift or on-call schedule look like?" and, for accredited labs, "When is your next assessment?" Pitfall: limiting your questions to salary and vacation, or having none ready, which tells a supervisor you have not thought about the bench itself.
Practice with AI
Get personalized feedback on your answers with our AI-powered mock interview simulator.
Start Free PracticeKey Skills to Highlight
Question Categories
behavioral
Questions about your past experiences and how you handled specific situations
technical
Questions about your technical skills, knowledge, and expertise
situational
Hypothetical scenarios to assess how you would handle future challenges
general
Common questions about your background, goals, and fit for the role
Related Interview Guides
More Healthcare Interview Guides
Explore 13 more healthcare resources.
Frequently Asked Questions About Laboratory Technician Interviews
Is there a practical test in a lab technician interview?
Some employers add a hands-on or written task, such as a gravimetric pipetting check, preparing a dilution from a stock, a short calculations and WHMIS quiz, or reading a chromatogram. Assessors usually watch technique as closely as the answer: changing tips, recording as you go, labelling what you make and cleaning up. Ask the recruiter what format to expect and whether a calculator is allowed.
How are lab technologist interviews different from lab technician interviews?
In Canadian clinical labs, medical laboratory technologists run analytical testing and review results, so their interviews go deeper into analyzer QC, result interpretation and critical values, while assistant and technician interviews focus on specimen collection, processing and labelling. In the US, a medical laboratory technician usually holds an associate degree, often with ASCP certification, and runs routine analyzer testing under a medical laboratory scientist or technologist, so expect instrument and QC questions in either interview. In research and industrial labs the two titles overlap, so the listed duties are the better guide to how technical the questions will get.
How do I answer medical lab technician interview questions if my only experience is a practicum?
Treat the clinical placement as real experience: name the departments you rotated through, such as [chemistry, hematology and microbiology], the analyzers you used and the tasks you did under supervision. Have one placement story about a specimen problem or QC issue and how it was handled. Say where you are in certification or registration, with your exam date if you have one.
Do I need WHMIS training before a lab interview?
Employers must train workers on WHMIS for their own workplace, so you will get site-specific training after you start, whatever certificate you already hold. A current WHMIS certificate from a course or college program still shows you know labels and safety data sheets, and some postings ask for one. Ask what other training the lab requires, such as biosafety or shipping specimens and dangerous goods.
Ready to Ace Your Laboratory Technician Interview?
Create a free JobEase account to practise your answers.